TS930.1 You may desire to switch this reduced tuning rate on and off. For example, you can select the new rate on just VFO B by using an unused section of the "FUNCTION" switch. Another possibility is to use the display "DIM" switch. 3) There are an additional 8 memories available. These can be obtained by grounding pin 5 of connector 7 on the DIGITAL UNIT. (This lead is designated "M3"). The 8 additional memories can be selected by using an unused contact on the "FUNCTION" switch. 4) Each group of 8 memories can be scanned at a rate of about 1 per second. Unlike a normal scanner, The unit will not stop scanning when a signal is present, but it is a good way to search favorite frequencies for activity. A method of turning on the scan function without affecting normal switch functions would be to wire the unused section of the DIAL LOCK switch in series with the unused section of the METER switch (meter switch in the "VC" position). 5) A handy option is to be able to momentarily unlock one VFO when the DIAL LOCK is on. This can be useful during split frequency operation when you want to keep the receive vfo locked (the DX station's xmit freq), yet quickly qsy to the frequency he is listening to with your transmit VFO. This change can be made by wiring one lead from the DIAL LOCK switch in series with extra normally closed contacts of the "T-F" switch.